3 Phase Squirrel Cage Induction Motor Three Phase Asynchronous Motor
Product overview
Squirrel Cage Induction Motor of high-efficiency high-voltage motors have four types of enclosure protection grades: IP23, IPW24, IP44 and IP54 according to the standards of GB4942.1 and IEC34-5 "Enclosure Protection Grades for Rotating Electric Machines". IP23 motors can be made into IP44 (duct ventilation) according to user requirements. If users need other protection grades, they can be supplied separately.
The cooling methods of YX, YXKS, YXKK series high-efficiency
high-voltage motors are IC01, IC611 and IC81W according to the
standards of GB/T1993 and IEC34-6 "Cooling Methods for Rotating
Electric Machines" respectively. If users need other cooling
methods, they can be supplied separately.
Starting of squirrel cage asynchronous motors (Y, YKS, YQF, YKK
series)
The rotor of the squirrel-cage asynchronous motor adopts advanced
computing technology to calculate the starting temperature rise and
stress of the squirrel-cage rotor, so as to prevent the motor from
early damage due to excessive starting load. Users are advised to
check:
(1) The moment of inertia of the rotating part of the driven
mechanical equipment (converted to the motor speed) should not
exceed the value of the item [Load J] in the technical data sheet;
(2) The user's power grid should ensure that the motor terminal
voltage of the motor during the starting process is not lower than
85% of the rated voltage;
(3) The resistance torque characteristics of the driven machinery
are the resistance torque characteristics of pumps and fans.
Under the above conditions, the motor is allowed to start twice
continuously in the actual cold state, and the motor stops
naturally between the two starts; or starts once in the hot state
of the motor. Restarting the motor beyond the above limit should be
done after stopping for 1 hour.
If the moment of inertia of the mechanical rotating part of the
motor drive is required to exceed the (load J) value in the
technical data sheet, or the motor is required to be started
frequently, or the motor may be started with a heavy load, be sure
to contact our company in advance to negotiate, so that special
Designed to ensure reliable starting of the motor.
Product specifications
frame(center high) | 355/500/630/710/800/1000 | IP | IP54/IP44/IP55 |
Voltage | 3KV, 6KV, 10KV | Poles | 2,4,6,8,10,12 |
Frequency | 50HZ/60HZ | Insulation class | F;H |
Speed | 500/590/740/990/1500/3000RPM | Efficiency | 84-94.5% |
Installation | IMB3,IMB5,IMB35 | Standard | IEC, GB |